Space shuttle dropped down the trapped proton doses at international space station

Authors

  • Tsvetan Dachev
  • Jordanka Semkova

DOI:

https://doi.org/10.46687/jsar.v1i1.25

Abstract

The data from three Bulgarian build instruments on the International Space Station (ISS): Liuin-5 inside PIERS module of Russian segment, R3DE instrument outside at the European Technological Expose Facility (EuTEF) on the ESA Columbus module and R3DR instrument outside Russian “Zvezda” module shows that the docking of the Space Shuttle with the ISS decreased the trapped proton maximal doses in the region of the South-Atlantic Anomaly (SAA) by factor of 1.25 to 2 in dependence from the local shielding and the distance to the Space Shuttle. The analysis of the ascending/descending SAA dose rate maximums of the instruments shows that the effect can be simply explained by the additional shielding against the 30 to 150 MeV protons of the inner radiation belt in the region of the SAA, provided by the 78 tons Shuttle to the instruments and by changing of the ISS 3D mass distribution when the ISS rotates.

Author Biographies

Tsvetan Dachev

Space Research and Technology Institute, Bulgarian Academy of Sciences, Sofia, Bulgaria

Jordanka Semkova

Space Research and Technology Institute, Bulgarian Academy of Sciences, Sofia, Bulgaria

References

Dachev, Ts.P., Tomov, B.T., Mat-viichuk, Yu.N., Dimitrov, P.G., Bankov, N.G., Relativistic Electrons High Doses at International Space Station and Foton M2/M3 Satellites, Adv. Space Res., 1433- 1440, 2009a. doi:10.1016/j.asr.2009.09.023

Reitz, G. R. Beaujean, E. Benton, S. Burmeister, Ts. Dachev, S. Deme, M. Lus-zik-Bhadra, and P. Olko, Space radiation measurements on-board ISS—the DOS-MAP experiment, Radiat Prot Dosimetry, 116, 374-379, 2005.

Simpson, J.A., in: Shapiro M.M.

(Ed.) (1983) Composition and origin of cosmic rays, NATO ASI Series C: Mathe-matical and Physical Sciences 107, Reidel, Dordrecht, 1983.

Horneck G. HZE particle effects in space. Acta Astronaut 32:749-755, 1994. [5] Smart, D.F., Shea, M.A. (2005) A review of geomagnetic cut off rigidities for earth-orbiting spacecraft. Adv. Space Res. 36:2012–2020.

Slaba, T.C., S.R. Blattnig, F.F. Badavi, N.N. Stoffle, R.D. Rutledge, K.T. Lee, E.N. Zappe, T.P. Dachev and B.T. Tomov, Statistical Validation of HZETRN as a Function of Vertical Cutoff Rigidity using ISS Measurements, Adv. Space Res., 47, 600-610, 2011. doi:10.1016/j.asr.2010.10.021

Dachev, Ts.P., Characterization of near Earth radiation environment by Liulin type instruments, Adv. Space Res., 44, pp 1441-1449, 2009. doi:10.1016/j.asr.2009.08.007

Semkova J., R. Koleva, St. Maltchev, N. Bankov, V. Benghin, I. Chernykh, V. Shurshakov, V. Petrov, S. Drobyshev, I. Nikolaev, Depth dose meas-urements with the Liulin-5 experiment in-side the spherical phantom of the Ma-troshka-R project onboard the International Space Station, Advances in Space Research 49 (2012) 471–478, http://dx.doi.org/10.1016/j.asr.2011.10.005

Shurshakov, V. A, Akatov, Y., Kart-sev, I. S., et al. Measurements of the ab-sorbed dose distribution in the spherical tissue equivalent phantom in MA-TROSHKA-R space experiment, 11th WRMISS, United Kingdom, Oxford, 2006. http://www.wrmiss.org/workshops/eleventhReitz G., Berger, T., The MA-TROSHKA facility – dose determination during an EVA, Radiat. Prot. Dosim., 120, 442–445, 2006.

Dachev, T.P., J. Semkova, B. Tomov, Yu. Matviichuk, Pl. Dimitrov, R. Koleva, St. Malchev, G. Reitz, G. Horneck, G. De Angelis, D.-P. Häder, V. Petrov, V. Shurshakov, V. Benghin, I. Chernykh, S. Drobyshev, N. G. Bankov, Space Shuttle drops down the SAA doses on ISS, Adv. Space Res., 47, 2030-2038 2011.

doi:10.1016/j.asr.2011.01.034

Heffner, J. Nuclear radiation and safety in space. M. Atomizdat., 115, 1971. (in Russian)

Semones, E. et al., ISS TEPC Meas-urement Results, Paper presented at 13 WRMISS workshop, 2008, Krakow, Po-land, 8-10 September 2008. http://wrmiss.org/workshops/thirteenth/Sem ones_TEPC.pdf

Drobyshev S., Benghin V., Influence of the International Space Station Attitude on Dose Rate in the Service Module of the Station when Crossing the South-Atlantic Anomaly, Sozopol, Bulgaria, June 6-10 2011. http://www.stil.bas.bg/WS-

sozopol/2011Sozopol/Drobyshev2011_Sozop ol.pps

Dachev, Ts., W. Atwell, E. Semo-nes, et al. Observations of the SAA radia-tion distribution by Liulin-E094 instrument on ISS, Adv. Space Res. 37 (9), 1672–1677, 2006

Wilson, J. W., J. E. Nealy, T. Dachev, B.T. Tomov, et al, Time serial analysis of the induced LEO environment within the ISS 6A, Adv. Space Res., 40, 11, 1562-1570, 2007.

doi:10.1016/j.asr.2006.12.030

Easley, S. M., Anisotropy in the South At-lantic Anomaly, Master thesis, Report Number A618464, Jan. 2007.

http://www.stormingmedia.us/61/6184/A61 8464.html

Downloads

Published

25.02.2023

How to Cite

Dachev, T., & Semkova, J. (2023). Space shuttle dropped down the trapped proton doses at international space station. JOURNAL SCIENTIFIC AND APPLIED RESEARCH, 1(1), 87–97. https://doi.org/10.46687/jsar.v1i1.25